We use cookies to continually improve our website. The further use of our website confirms your acceptance of these cookies. More information Close
Sauerland Spanplatte

By mechanical tests the resistance of doors regarding:  

The load acting up the door is increased according to the performance classes shown in the table. 

 

 

Figure: soft body

Performance
Classes
N
normal
M
medium
S
strong
E
extreme
Lab Tests
- static distortion200 N250 N300 N  350 N
- dynamic distortion400 N600 N800 N1000 N
- soft body
(30kg sandbag)
100 mm
height of fall
30 J energy
200 mm
height of fall
60 J energy
400 mm
height of fall
120 J energy
600 mm
height of fall
180 J energy
- hard body
(500g steel-ball)
300 mm
height of fall
1,5 J energy
500 mm
height of fall
3 J energy
1000 mm
height of fall
5 J energy
1600 mm
height of fall
8 J energy
Recommended Use
- domesticO
- flat entranceO
- officeOO
- schoolO
- hospitalOO
- hotelOO

Possible Constructions:
The mechanical characteristics are influenced by:

  • frame ⇒ material and construction
  • skin ⇒ material and thickness
  • core ⇒ full size and compression resistant core 

Application of SAUERLAND BOARD :
Full size tubular and solid board cores meet the requirements of all the three performance classes.